GS-SD-500

Sliding Door Autoclave

Fully automatic microprocessor‑controlled horizontal steam sterilizer with vertical sliding door.

  • Construction: All‑weld SS 316 chamber & jacket
  • Door: Vertical sliding, SS 316, silicon gasket with compressed air seal
  • Control: PLC + 4-5" color touch HMI, password protection
  • Safety: Self-locking door, auto alarms, low-water cut-off
  • Vacuum: Multistage liquid ring pump for pre-vacuum
  • Temperature: 121°C – 134°C • Pressure: 50–80 PSIG
Temp: 121 – 134 °C Voltage: 440VAC, 50 Hz, 3Φ Pressure: 50 – 80 PSIG Material: SS 316
GS-SD-500 Sliding Door Autoclave
GS-SD-500 Sliding Door Fully Automatic
👆 Replace this with your actual product image

Construction & Door

  • Construction: Robust and rugged all-weld construction which is leak-proof, unlike riveted construction. Chamber and jacket are made of a thick plate of stainless steel of 316.
  • Hollow Load Test: Pass a hollow load (A) test (batch Monitoring System) High Vacuum compressor with recycling facility.
  • Door Type: Vertical sliding single/double door, fabricated from SS 316 quality material.
  • Door Sealing: Sealing is done through a movable silicon gasket pressurized by compressed air. Pressure gauge provided for gasket.
  • Insulation: Glass wool insulation ensures surface temperature < 45°C, has low thermal conductivity, and does not release particles.
  • Door Gasket: Silicon gasket, pressed against the rear face of the door by steam/air during the process to ensure the doors remain closed.

Control System PLC + HMI

  • Controller: Fully automatic microprocessor controlled horizontal steam sterilizer.
  • Interface: PLC-based system with 4-5" color touch-sensitive LCD display interface.
  • Battery back-up & non-volatile memories.
  • Digital input/output controls, analog measuring inputs & ports for PC connectivity.
  • Password Protection: Multiple password access levels to control access/operation, preventing unauthorized access.
  • Printer: Equipped with built-in thermal printer.

Safety & Alarms

  • Self-locking safety door – cannot be opened when chamber is under pressure.
  • Automatic process checking & failure correction.
  • Self-diagnosis with audio/visual alarms.
  • Heaters shut off if water falls below preset level.
  • Terminals & contacts housed in a watertight cabinet.
  • Electronic water saving control – condenses exhaust steam & prevents pollutants from entering water supply.
  • Alarms for: over temperature, pressure sensor failure, phase time out, doors not closed, power failure (<10 sec ignored).
  • Continuous self-checking of all safety devices, low water level, water in chamber, etc.
  • Steam Generator & Vacuum System

    • Steam Generator: Separate generator of suitable capacity, made of SS 316, fitted with all safety & control devices.
    • Automatic Water Level: Energizes the water pump and supply valve to ensure proper water level in the boiler drum.
    • Vacuum System: Electric multistage liquid ring vacuum pump ensures air removal during the pre-vacuum stage.
    • Temperature Range: Working temperature 121 °C to 134 °C.
    • Power: 440VAC, 50 Hz, 3 Phase.
    • Steam Quality: Condensate free 97-100 % saturated vapor, complete with piping, valves, and pressure relief, delivery at 50-80 PSIG pressure.

    Air Filter & Sterilization Cycles

    • Air Filter: A disposable air filter is provided for filtering atmospheric air entering the chamber.
    • Programs: Designed to operate various programs. Apart from standard pre-programmed cycles, a special cycle can be programmed by an authorized supervisor code only.
    • Wrapped Instruments: Porous load at 134°C.
    • Heat Sensitive / Rubber / Plastic: Porous load at 121°C (working holding temperature 121°C to 134°C).
    • Test Cycles: Bowie & Dick test (7kg), PCD test, Leak test.
    • Modes: Equipped with pre-vacuum, gravity, and preferably liquid cycle (121°C Liquid cycle for liquids, no drying time).
    • Completion: Automatic cycling and drying, indicating completion both visually and audibly.

    Loading / Unloading & Documentation

    • Internal Carriage: Sterilizers have SS 304 internal carriage/trolley.
    • External Trolleys: 2 No.'s External trolley/carts equal to chamber depth for easy loading and unloading.
    • Operation Manual: Provided in English at the time of machine supply.
    • Certificates: Calibration Certificate and Warranty Certificate included.

    Size & Load

    Inner Chamber (W × H × D) Capacity (Liters) Load (kW)
    450 × 450 × 900 mm180 L18 kW
    450 × 600 × 900 mm240 L18 kW
    600 × 600 × 900 mm320 L18 kW
    600 × 600 × 1200 mm430 L27 kW
    600 × 900 × 1500 mm810 L27 kW
    ✦ Customized sizes available on request
    Sliding Door Autoclave — GS-SD-500 — Specifications subject to change without notice.